There is the possibility of misconfiguration, but ultimately, a member can be too weak even if the configuration is correct.
- 0 Posts
- 3 Comments
Joined 1 year ago
Cake day: March 4th, 2025
You are not logged in. If you use a Fediverse account that is able to follow users, you can follow this user.
If a member fails it is in fact because it is too weak. It would pass the utilisation check otherwise.


No, we would not. The beams have a loading that they must adequately support. They have a span that is dictated by the column spacing. There are moment, shear and deflection requirements that must be met.
You cannot just throw in supports (i.e., columns, bracing) everywhere to reduce the span until it works, otherwise you impact the usability of the building space and drive up the cost of construction.
Reducing the beam to beam spacing means you are increasing the number of structural elements and therefore cost, and probably also using the material inefficiently. The expensive part of a beam is the connection, and you typically want to reduce the number of connections and crane lifts as much as possible.